Cables and Wires for Data Centres: What to Consider
From power supply to data transmission, learn what users need to consider when planning, selecting, and installing cables in data centres.
Cloud applications, artificial intelligence, and networked processes represent significant challenges for data centres. Electrical connection technology is an important foundational component for their operation, supplying the infrastructure with power and enabling the transmission of data. But which cables are needed, and what should planners and operators pay attention to?
What roles do cables and wires play in data centres?
Cabling connects the various areas of the infrastructure. Power cables supply servers, distributors, uninterrupted power supplies, and cooling systems with power. Data cables and fibre-optic cables enable communication between IT systems and the connection to external networks. There are also cables for monitoring and controlling building automation.
Cable selection depends on the specific role. While current carrying capacity and installation conditions are important for power supply, data connections focus on transmission rates, range, and connection concept.
Copper or fibre-optic: Which data cable is right for my application?
For structured copper cabling, cable category and transmission distance are determined based on the Ethernet application. It is important to consider the required data rates, the distance, and the connectors being used.
Fibre-optic cables, in particular, are used for applications with high data transmission speeds and larger distances. For 400 and 800 Gbit/s Ethernet, there are already standardised transmission solutions. Whether single-mode or multi-mode fibres are used depends on, for instance, the distance and the transceivers being used. Even the connectors must selected according to the chosen cables.
Fibre channels, for instance, can be found in storage networks. Depending on the interface, the transmission protocol can be implemented with fibre-optic or copper cables.
Which standards are relevant around the globe?
The standards and approvals that must be observed depend on the location and the requirements of the project in question. Internationally, the ISO/IEC 22237 range provides a framework for data centre facilities and infrastructures. For application-agnostic communication cabling, the ISO/IEC 11801 series becomes relevant—for data centres, particularly part 5.
In Europe, the standard series EN 50600 creates an important foundation for planning. In Germany, it has been published as DIN EN 50600, where parts 2–4 deal with the infrastructure of telecommunications cabling. These are accompanied by DIN EN 50173-5 and the series DIN EN 50174 which are relevant for the cabling in computer rooms and for installation planning and execution, respectively.
In North America, the ANSI/TIA-942, amongst others, please a role when it comes to data centre infrastructure and locally applicable installation and fire-safety regulations. Depending on the type of cable and the conditions, additional UL or CSA certifications may be required.
That is why the standards, product approvals, and local regulations must be considered together when planning international projects. The approval of a product in one country does not mean it is approved in others.
Fire safety: What to consider
For cables and wires subject to the applicable construction product requirements, reaction-to-fire performance must be taken into account in accordance with EN 50575. The required reaction to fire class is determined by the applicable building regulations and the fire safety strategy. Depending on the installation location and fire safety strategy, cables and wires with a reaction to fire classification of Cca or B2ca, for example, may be required under the European Construction Products Regulation (CPR). The selection process must also take into account the relevant additional classifications for smoke production, flaming droplets and acidity.
It is important to distinguish clearly between “halogen-free”, “flame-retardant” and “circuit integrity”, as each describes a different characteristic. A halogen-free cable therefore does not automatically meet all the requirements of a particular installation. US approvals for so-called plenum spaces do not replace the European assessment.
How can availability be improved?
Redundancy must also extend to the cabling. Multiple connections alone are not enough. The key is to minimise common causes of failure wherever possible. Depending on the availability strategy, this may require separate cable routes and power supply and network infrastructure designed accordingly. Planning should be based on a risk assessment and the target availability class.
What makes for effective cable management?
Cable routes should remain accessible and minimise disruption to airflow wherever possible. Clear labelling and up-to-date documentation make maintenance, troubleshooting, and future expansion easier. Professional installation and appropriate testing are equally important.
For metallic data cables, electromagnetic compatibility must also be factored into the design. Screening can help limit interference, but it is no substitute for correct cable routing and installation. Fibre-optic cables transmit information using light, making the transmitted signal immune to electromagnetic interference.
What developments should planners keep an eye on?
AI applications are placing greater demands on computing power and energy supply. Data transmission, power supply, and cooling should therefore be considered together. For cabling, this means planning ahead for the required capacity headroom, available cable routes, and future expansion. This approach creates an infrastructure that can adapt to changing requirements.