What are plastic cable glands? HELUTOP® HT specifications and sizes

A plastic cable gland is a cable gland whose body and cap nut are made of engineering plastic, most often polyamide PA6. Plastic glands are lightweight, insulating, rust-free and cheaper than metal glands, which makes them the default choice for control cabinets, junction boxes and factory machinery. HELU's HELUTOP® HT range is rated IP68 at 5 bar and IP69K, operates from −20 °C to +100 °C, and is available with metric, PG and NPT threads. This article covers the specifications, size tables and how to choose the right plastic cable gland for your application.

HELUKABEL | APPLICATIONS OF HELUTOP® HT CABLE GLANDS

1. What are plastic cable glands?

A plastic cable gland is a cable gland whose main parts are made of engineering plastic. It guides a cable into a control cabinet, junction box or equipment housing. When the cap nut is tightened, the clamping lamellae press the rubber seal around the cable sheath. This holds the cable firmly so it cannot be pulled out, and seals the entry point against water and dust.

The most common material is polyamide (PA, also known as nylon). It does not rust, resists abrasion and impact well, and withstands fuels and many common cleaning agents. Some special ranges use PVDF plastic for stronger chemical resistance. For a general overview of how cable glands are built and what they do, see What are cable glands?

Construction of a plastic cable gland
Construction of a plastic cable gland

2. Plastic or metal cable glands: which should you choose?

Plastic cable glands are sufficient for most control cabinets and machines in normal factory conditions. You only need metal glands when there is heavy vibration, aggressive chemicals, strict hygiene requirements or a need for EMC screening.

CriteriaPlastic glands(PA6)Nickel-plated glandsStainless steel glands
Weight
Lightest
Heavy
Heavy
Electrical insulation
Yes
No (conductive)
No (conductive)
Mechanical strength
Good
Very good, vibration-resistant
Very good
Corrosion resistance
Rust-free, resists fuels and cleaning agents
Good thanks to nickel plating
Excellent, resists cleaning agents and disinfectants
EMC screening
No
Yes (dedicated EMC ranges)
Yes (dedicated EMC ranges)
Price
Lowest
Medium
Highest
Best for
Control cabinets, junction boxes, general automation machinery
Industrial machines with heavy vibration, vehicles, railways
Food, pharmaceutical and chemical plants, outdoor use

Plastic glands also have limits: the body can crack if overtightened, and they cannot be used where the cable screen must be earthed. For a more detailed comparison between plastic and brass, see the FAQ on brass cable glands .

3. HELUTOP® HT plastic cable gland specifications

HELUTOP® HT is HELU's vibration-resistant plastic cable gland, made of polyamide PA6 with a chloroprene rubber seal. It is tested to EN 50262 and carries VDE and UL approvals for some metric sizes.

PA6 plastic gland: HELUTOP HT-BS
PA6 plastic gland: HELUTOP HT-BS
SpecificationsValue
Body and cap nut
Polyamide PA6
Seal
Chloroprene rubber (CR)
Protection
IP68 at 5 bar, IP69K
Operating temperature
−20 °C to +100 °C
Test standard
EN 50262
Composition
Free of phosphorus, silicone and cadmium
Colours
Light grey RAL 7035, dark grey RAL 7001, black RAL 9005
Threads
Metric M12 to M63, PG7 to PG48, NPT 3/8" to 1"
Approvals
VDE and UL for some metric sizes

IP68 at 5 bar means the gland withstands water pressure equal to a depth of 50 m for 30 minutes. IP69K means it withstands high-pressure hot water jets during machine cleaning. Both ratings only apply when the cable diameter is within the clamping range and the gland is tightened correctly.

4. Features and applications of the HELUTOP® HT plastic gland

4.1 Key Features

FeaturesBenefits
Clamping lamellae for strain relief
The cable is held firmly, so terminals inside the cabinet are protected from external pulling forces
Wide clamping ranges
One gland size fits several cable sizes, reducing the number of part numbers to stock
Vibration-resistant design
The cap nut does not loosen on its own when machines run continuously
No disassembly needed
Just loosen the cap nut, insert the cable and tighten again, with no loose parts to lose
Free of phosphorus, silicone and cadmium
Suitable for paint lines and production areas with material restrictions

4.2 Applications

HELUTOP® HT plastic cable glands are used at almost every point where cables enter cabinets or equipment in a factory, including:

  • Machine building and plant construction
  • Robotics and automation
  • Shipbuilding and vehicle construction
  • Railway technology
  • Building electrical installation
  • Control cabinets and distribution boards

View detailed applications for each product in the HELUTOP® HT line

5. HELUTOP® HT plastic cable gland sizes

Choose the gland size by the cable's outer diameter, then choose the thread type that matches the hole in the enclosure. If the cable fits the clamping range of two sizes, pick the one where the cable sits closer to the middle of the range, so the rubber seal grips more evenly and seals better.

5.1 Metric thread plastic cable glands

Thread sizeClamping range (mm)Thread length (mm)Spanner size (mm)
M12x1.5
3.0 to 6.5
8.0
15
M16x1.5
4.0 to 8.0
8.0
19
M16x1.5
5.0 to 10.0
8.0
19
M20x1.5
6.0 to 12.0
10.0
24
M25x1.5
11.0 to 17.0
8.0
29
M32x1.5
15.0 to 21.0
10.0
36
M40x1.5
19.0 to 28.0
10.0
46
M50x1.5
30.0 to 38.0
18.0
60
M63x1.5
34.0 to 44.0
18.0
65

5.2 PG thread plastic glands

Thread sizeClamping range (mm)Thread length (mm)Spanner size (mm)
PG7
3.0 to 6.5
8.0
15
PG9
4.0 to 8.0
8.0
19
PG11
5.0 to 10.0
8.0
22
PG13.5
6.0 to 12.0
9.0
24
PG16
10.0 to 14.0
10.0
27
PG21
13.0 to 18.0
11.0
33
PG29
18.0 to 25.0
11.0
42
PG36
22.0 to 32.0
13.0
53
PG42
30.0 to 38.0
13.0
60
PG48
34.0 to 44.0
14.0
65

For entry hole sizes and PG to metric conversion, see the PG cable gland article .

5.3 NPT thread plastic cable glands

Thread sizeClamping range (mm)Thread length (mm)Spanner size (mm)
3/8" NPT
5.0 to 10.0
15.0
22
1/2" NPT
6.0 to 12.0
15.0
24
1/2" NPT
10.0 to 14.0
15.0
27
3/4" NPT
13.0 to 18.0
15.0
33
1" NPT
18.0 to 25.0
18.0
42

HELUTOP® HT is also available with metric threads and a reducing seal for smaller cables; for example, the M20 version clamps cables from 5 to 9 mm. Each size comes in light grey, dark grey and black. Contact HELU for the exact part numbers.

6. HELU’s HELUTOP HT plastic gland portfolio

ProductsFeaturesData sheet
HELUTOP HT RJ45For pre-assembled RJ45 cables 11024765
HELUTOP® HT-PA-EXExplosion-proof, for hazardous areas 906691
HELUTOP® EasyNo threaded connector 908054
HELUTOP® HT-PA-EX-Plus  908080
HELUTOP® HT-PA-EX-Plus Silicone  908105
HELUTOP® HT-AIR-PAIntegration of the pressure compensation and ventilation systems 906990
HELUTOP® HT UVUV-resistant, VDE-certified 93937
HELUTOP® HT PA6Meets VDE standards 93908
HELUTOP® HT-KMeets VDE standards 93867
HELUTOP® HT-BSMeets VDE standards 94530

7. Other HELU plastic cable glands

Besides HELUTOP® HT, HELU offers many plastic cable gland ranges for specific needs, from moving cables and multiple cables through one hole to hazardous areas.

RequirementProductsKey features
Standard applications, wide clamping range
HSK
IP68 at 10 bar and IP69K, −40 °C to +100 °C, blue version for intrinsically safe circuits
Several cables through one hole
UNI-DICHT-MFDE Sealing insert with several holes, one per cable
Cable entering equipment at a right angle
HSK-WI
Elbow-shaped gland body
Aggressive chemicals
HSK-PVDF
PVDF plastic body with high chemical resistance
Areas with flammable gas or dust
HSK-EX-Active
ATEX certified for hazardous areas
Quick installation without a thread
HELUFAST
Push into the enclosure hole and lock by hand

If you need a gland that handles vibration and impact better, you can choose HELUTOP® HT-MS nickel-plated cable glands . For food and pharmaceutical facilities that require high-pressure steam cleaning, use HELUTOP® HT-Clean stainless steel glands . A complete list of product lines is available on the cable gland overview page .

Need advice on choosing the right size or a quote for plastic glands?

Please provide HELU Vietnam with the cable type, outer diameter, thread type on the enclosure, and installation environment. Our technical team will recommend the appropriate product code via the contact form or Zalo.

8. Frequently Asked Questions

Yes. The HELUTOP® HT plastic glands meet IP68 at 5 bar and IP69K, and are resistant to immersion and high-pressure water jets. A watertight seal is achieved only when the cable is within the clamping range and the glands are tightened to the correct torque.

HELUTOP® HT operates reliably from −20 °C to +100 °C. The HSK series has a wider operating range, from −40 °C to +100 °C.

It can be used, but plastic will age faster than metal when left in the sun for a long time. For locations exposed to direct sunlight over an extended period, you should choose UV-resistant cable glands or consider stainless steel ones.

HELUTOP® HT PG7 is designed for cables with an outer diameter ranging from 3 to 6.5 mm, and features a clamping range compatible with M12 metric threads.

HELUTOP® HT PG16 is designed for cables with an outer diameter ranging from 10 to 14 mm, such as the JZ-500 5G4 control cable (approximately 12.1 mm).

When the machine vibrates heavily, there is a risk of mechanical impact; therefore, it must be grounded via an EMC shielding layer or installed in food or pharmaceutical facilities where cleaning with chemicals and high-pressure steam is required.