HELUTOP® HT-Clean: IP69-rated hygienic cable gland for the F&B and Pharmaceutical industry

HELUTOP® HT-Clean is HELU's stainless steel cable gland for areas with strict hygiene requirements, such as dairy, meat, beverage and pharmaceutical plants and clean rooms. Its smooth stainless surface with no exposed threads makes it hard for microorganisms to adhere and faster to clean. It is rated IP69 and IP68 5 bar, and withstands high-pressure steam cleaning and cleaning chemicals. HT-Clean comes in metric sizes M12 to M25, with an additional HT-Clean-EMV version for screened cables. For a general guide to stainless steel cable glands, including how to choose the steel grade and IP rating, see the dedicated article.

HELUTOP® HT-Clean - Stainless Steel Cable Clamps

1. Construction and materials of HELUTOP® HT-Clean

Each part of HT-Clean is made of a material chosen to withstand food industry cleaning routines. The strain relief element is separate from the seal, so the cable is held firmly while the seal stays reliable.

PartMaterials
Body and cap nut
Stainless steel 1.4305 (AISI 303)
Strain relief
POM plastic
Seal (grommet)
TPE compliant with FDA 21 CFR 177.2600 for food-contact materials
Locknut
Included on delivery
HELUTOP® HT-Clean Stainless Steel Cable Clamp
HELUTOP® HT-Clean Stainless Steel Cable Clamp

2. Technical specifications of HELUTOP® HT-Clean

Specifications
Value
Ingress Protection
IP 69 / IP 68 - 5 bar
Operating temperature
−20 °C to +100 °C
Short-term temperature
−40 °C to +150 °C
Thread systemMetric threads: M12, M16, M20, M25
Clamping rangeFrom 3 mm (M12) to 17 mm (M25)
EMC version
HELUTOP® HT-Clean-EMV , sizes M16 to M25

IP68 means it is completely dustproof and can withstand submersion in water. A rating of 5 bar is equivalent to the water pressure at a depth of 50 meters for 30 minutes.

Data sheet of HELUTOP® HT-Clean

3. The hygienic design of HELUTOP® HT-Clean

In food plants, the threads and edges of standard cable glands are where dirt and microorganisms tend to build up. HT-Clean is designed to remove these traps.

FeaturesBenefits
Smooth stainless steel surface
Microorganisms struggle to adhere; cleaning is faster and cheaper
No exposed threads
No thread gaps left to hold residue after cleaning
Withstands high-pressure steam cleaning
Compatible with daily machine cleaning routines in food plants
Resistant to cleaning chemicals
Does not corrode or degrade when exposed to cleaning agents and disinfectants
High tightness
Water and dirt cannot enter the equipment
Strain relief separate from the seal
Holds the cable firmly without reducing seal performance

4. Applications of HELUTOP® HT-Clean

HELUTOP®HT-Clean suits any cable entry in production areas that are cleaned frequently:

  • Dairy and meat processing
  • Food packaging machines
  • Beverage production
  • Pharmaceuticals
  • Clean rooms
  • Biotechnology
  • Chemical industry

For motors, sensors or controllers with screened cables in these areas, choose the HELUTOP® HT-Clean-EMC version, which keeps the hygienic design and also earths the cable screen.

List of ECOLAB®-certified cables and accessories for the F&B industry

HELUTOP HT-Clean is suitable for areas in F&B facilities that come into direct contact with food
HELUTOP HT-Clean is suitable for areas in F&B facilities that come into direct contact with food

5. HELUTOP® HT-Clean dimensions (metric threads)

HELUTOP HT-Clean is available with metric threads only, in four sizes from M12 to M25. Choose the size by the cable's outer diameter, preferring a size where the cable sits near the middle of the clamping range.

Thread size
Clamping range (mm)
Thread length (mm)
Spanner size (mm)
Cap nut torque (Nm)
Locknut torque (Nm)
M12x1.5
3.0 to 6.5
6.0
14
2.5
6
M16x1.5
5.0 to 10.0
7.0
18
4
9
M20x1.5
6.0 to 12.0
10.0
22
5
12
M25x1.5
12.0 to 17.0
14.0
28
6
14

The HELUTOP® HT-Clean-EMV version is available in sizes M16, M20, and M25, with the same cable clamping range and a body that is approximately 5 to 8 mm taller.

Notes on installing HELUTOP®-HT-Clean steel glands

The product is delivered with a locknut and can be fitted with a standard socket wrench. When tightening from outside the housing, use the dedicated tightening tool HELU supplies for each size. Tighten to the torque values above to achieve IP68 and IP69 5 bar.

6. HELUTOP®-HT-Clean and other HELU stainless steel product lines

In addition to HELUTOP®-HT-Clean, HELU offers two other lines of stainless steel cable glands that also use AISI 303 stainless steel: HSK-INOX for general corrosive environments (available with threads ranging from PG7 to PG48) and HELUTOP® HT-E for heavy-duty applications. Choose HT-Clean when ease of cleaning is the top priority. A complete comparison table of the three product lines, along with guidance on selecting AISI 303, 304, and 316L stainless steel grades and IP ratings, is available in the article on stainless steel cable glands.

HELUTOP® HT-E stainless steel cable gland
HELUTOP® HT-E stainless steel cable gland

Need advice on selecting a size or a quote for HELUTOP® HT-Clean?

Please provide HELU Vietnam with the cable type, outer diameter, and the cleaning process used at your factory. Our technical team will recommend the appropriate product code via the contact form or Zalo.

7. Frequently Asked Questions About HELUTOP® HT-Clean

No. HELUTOP®-HT-Clean is made of 1.4305 stainless steel, also known as AISI 303. This type of stainless steel is easy to machine, suitable for threaded components such as cable clamps, and has been certified for use in food-contact applications.

No. HELUTOP®-HT-Clean is only available with metric threads: M12, M16, M20, and M25. If you need stainless steel screws with PG threads , please use the HSK-INOX series, which is available in sizes ranging from PG7 to PG48.

Yes. The HELUTOP®-HT-Clean stainless steel glands meet IP 69 / IP 68 - 5 bar standards, withstanding high-pressure hot water jets and steam during machine cleaning, and can withstand short-term temperatures up to +150 °C.

Use EMC protection version when cables with an electromagnetic interference (EMI) shield require grounding. For example, motor cables connected to inverters in food production lines - HELUTOP®-HT-Clean-EMV maintains the hygienic design while adding grounding functionality for the EMI shield.

If you still have questions, don’t hesitate to contact the HELU Vietnam engineering team for detailed answers.

HELU Vietnam Contact Information

HELU Vietnam
905 Nguyen Kiem Street, Hanh Thong Ward, Ho Chi Minh City, 700000, Vietnam
Phone: +84 28 77755578
Email: info@helukabel.com.vn
Connect with us on

Contact us via Zalo Information Contact Form Subscribe to the HELU Vietnam e-newsletter
Place an order through our
online channels : Tiki | Shopee | Lazada | Product Finder
Back