HELUTOP® HT-MS brass cable gland: Specifications & Applications

HELUTP HT-MS Cable Clamp

HELUTOP® HT-MS is HELU's nickel-plated brass cable gland, rated IP68 at 5 bar and IP69K, for operating temperatures from −20 °C to +100 °C. The metal body handles vibration and impact better than plastic, so it is widely used on industrial machinery, robots, vehicles and railway equipment. HT-MS is available with metric, PG and NPT threads. For a general introduction to this material, see what is a brass cable gland .

1. Construction of the HELUTOP® HT-MS brass cable gland

HELUTOP® HT-MS has the same design as the plastic HELUTOP® HT , but its body and cap nut are made of metal. Each gland has four main parts:

PartMaterialsFunction
Body and cap nut
Nickel-plated brass
Takes mechanical load, resists corrosion, keeps the thread durable over repeated fitting
Clamp
Polyamide PA6
Presses the seal onto the cable and relieves strain on the terminals
Seal
Chloroprene rubber (CR)
Grips the cable sheath and keeps out water and dust
O-ring
NBR
Seals the thread between the gland body and the housing
HELUTOP® HT-MS Copper Cable Clamp
HELUTOP® HT-MS Copper Cable Clamp

2. Specifications of HELUTOP® HT-MS

Some key specifications of the HELUTOP HT-MS include:

  • Ingress protection: IP68 at 5 bar, IP69K
  • Operating temperature: −20 °C to +100 °C
  • Short-term temperature range: −40 °C to +150 °C
  • Test standard: EN 50262
  • Thread sizes: Metric threads M12 to M63, PG threads PG7 to PG48, NPT threads 3/8" to 1"
  • Cable clamping range: From 3 mm (M12) to 55 mm (M63)

IP68 at 5 bar means the screw can withstand water pressure equivalent to a depth of 50 m for 30 minutes. The IP68 and IP69K protection ratings are achieved only when the cable is secured within the clamp and the screw is tightened to the correct torque.

Complete data sheet for the HELUTOP HT-MS

3. Features of the HELUTOP® HT-MS brass gland

The HELUTOP HT-MS stands out for the following advantages:

  • The screw body is made of nickel-plated brass: It offers better resistance to vibration, impact, and tightening forces than plastic cable screws, making it suitable for heavy-duty industrial environments.
  • Clamping lamellae for strain relief: The cable is held securely, and the internal connection point is not subjected to external tensile force
  • Wide clamping range: One screw size fits multiple cable sizes, reducing the number of SKUs that need to be kept in stock
  • Installation without disassembly: Simply loosen the cap, thread the cable through, and tighten it again
  • Short-term heat resistance up to +150 °C: Withstands temporary exposure to high temperatures near engines or heat sources

HT-MS is not an EMC range. If the cable has a screen that must be earthed, for example cables to frequency inverters or servo drives, use the HELUTOP® MS-E or HELUTOP® MS-EP EMC copper-clad cable series.

HELUTOP MS-EP
HELUTOP MS-EP

4. Applications of HELUTOP® HT-MS

HT-MS suits locations where plastic glands could crack or work loose because of vibration, impact or high tightening forces:

  • Machine building and plant construction
  • Robotics and automation
  • Shipbuilding and vehicle construction
  • Railway technology
  • Building electrical installation
  • Control cabinets and distribution boards

5. Dimensions of HELUTOP® HT-MS brass cable glands

Choose the size by the cable's outer diameter, then the thread type that matches the hole in the enclosure. If the cable fits two sizes, pick the one where the cable sits closer to the middle of the clamping range.

5.1 Metric System (M)

Thread sizeClamping range (mm)Thread length (mm)Spanner size (mm)
M12x1.5
3.0 to 6.5
6.0
14
M16x1.5
5.0 to 10.0
7.0
20
M20x1.5
6.0 to 12.0
8.0
22
M25x1.5
11.0 to 17.0
8.0
27
M32x1.5
15.0 to 21.0
9.0
34
M40x1.5
19.0 to 28.0
9.0
43
M50x1.5
27.0 to 38.0
10.0
58
M63x1.5
34.0 to 44.0
10.0
64 / 68
M63x1.5
44.0 to 55.0
10.0
75

5.2 PG threads

Thread sizeClamping range (mm)Thread length (mm)Spanner size (mm)
PG7
3.0 to 6.5
6.0
14
PG9
4.0 to 8.0
6.0
17
PG11
5.0 to 10.0
6.0
20
PG13.5
6.0 to 12.0
6.5
22
PG16
10.0 to 14.0
6.5
24
PG21
13.0 to 18.0
7.2
30
PG29
18.0 to 25.0
8.0
40
PG36
22.0 to 32.0
9.0
50
PG42
30.0 to 38.0
12.0
58
PG48
34.0 to 44.0
14.0
64

For more information on hole sizes and how to convert PG threads to metric threads, see the article on PG-system electrical cable glands .

5.3 NPT threads

Thread size
Clamping range (mm)
Thread length (mm)
Spanner size (mm)
3/8" NPT
4.0 to 8.0
11.5
17 / 19
1/2" NPT
6.0 to 12.0
13.0
22
3/4" NPT
13.0 to 18.0
13.0
30
1" NPT
18.0 to 25.0
13.0
40 / 43

The HT-MS is also available in a metric threaded version with a reducer gasket for smaller cables; for example, the M20 model can clamp cables ranging from 5 to 9 mm. Contact HELU Vietnam for specific product codes.

6. When to choose HT-MS over other ranges?

Choose HT-MS when you need a gland that is tougher than plastic but do not need stainless steel or EMC screening. The table below compares the most common HELUTOP® ranges.

ProductsMaterialsBest for
HELUTOP® HT
PA6 plastic
Control cabinets and general machinery where insulation and low cost matter
HELUTOP® HT-MS
Nickel-plated brass
Machines with heavy vibration, risk of impact, harsh industrial environments
HELUTOP® MS-E, MS-EP
Nickel-plated brass
Screened cables that need EMC earthing: frequency inverters, servo drives, robots
HELUTOP® HT-Clean
AISI 303 stainless steelFood and pharmaceutical plants require cleaning with steam and chemicals
HELUTOP® HT-MS-EX-d
HELUTOP® HT-MS-EX-d / e4
HELUTOP® HT-MS-EX-d 1 EMV
Nickel-plated brass ExFor hazardous areas, ATEX/IECEx-certified

For a more detailed comparison between brass, plastic, and stainless steel cable glands, see the article on frequently asked questions about brass cable glands .

Need advice on selecting a size or a quote for HELUTOP® HT-MS?

Please provide HELU Vietnam with the cable type, outer diameter, thread type on the enclosure, and installation environment. Our technical team will recommend the appropriate product code via the contact form or Zalo.

7. Frequently Asked Questions

No. HT-MS is a standard brass gland with no part that contacts the cable screen. If you need to earth the cable screen, use HELUTOP® MS-E or MS-EP.

HT-MS operates reliably from −20 °C to +100 °C and can withstand −40 °C to +150 °C for short periods.

Yes. HT-MS comes in all 10 PG sizes from PG7 to PG48, as well as metric M12 to M63 and NPT 3/8" to 1".

Both have the same design and the same IP68 and IP69K ratings. HT has a light, insulating PA6 plastic body, while HT-MS has a nickel-plated brass body that handles vibration and impact better and withstands higher short-term temperatures.

Back